Tél.: 450-692-0000 - Fax: 450-692-7567
Courriel:
info@balancesuniverselles.com

Calculatrice Conversion


English
Balances à convoyeur
.................................................................................................................................
Ramsey

Balances Ramsey

RAMSEY
Modèle : Série-IDEA  (141k)
Balance de convoyeur - +/- 1% précision 
 
Scale Module
Minimum Net Load @ Rated Capacity: 15% of Load Cell Capacity
Maximum Gross Load @ Rated Capacity: 80% of Load Cell Capacity
Available Load Cell Sizes: 20kg, 50Kg, 100Kg, 200Kg, 250Kg, 500Kg.
Maximum Belt Width: 10-101R-1: 36”
Maximum Belt Width: 10-101R-2: 60”
 
Loal Cell
Load Cell: Welded bending beam type load cell
Load Cell Output: 2.0 Mv/V, ± .1 %
Excitation: 10 VDC or VAC
Load Cell Rating: 3000d, meets OIML R60 & NIST HB-44
Temperature Range: Safe: -30 to +80 degrees C
Compensated: -10 to +40 degrees C
Overload: 150% of Rated Capacity
Input Impedance: 380 ohms ± 10
Output Impedance: 350 ohms ± 3
Environmental Protection: Hermetically Sealed, IP67
Load Cell Construction: Stainless Steel
Cable: 6 Conductor, Shielded, 22 AWG
 
Speed Sensor Model 60-1
Type: Digital, Brushless
Mounting: Direct to 5/8’ diameter stub shaft on tail pulley, bend pulley, or lagged return roll
Housing: Weather-tight
 
MINI 11-101 INTEGRATOR
Enclosure Field Mount
Dimensions: Height: 11.81 in (300 mm)
Width: 9.84 in (250 mm)
Depth: 6.30 in (160 mm)
Material: Polyester
Weight: 8.8 Ibs. (4 kg)
Protection: IP 65 (NEMA 4)
 
Environmental
Operating Temperature: Field mount version 14° to 122°F (-10° to +50°C)
Storage Temperature: -4° to 158°F (-20° to +70°C)
Humidity (operating & stocking): <90% (without condensation)
 
Power Requirements
Voltage: Standard - 110 or 220 VAC selectable, +10%-15%
Frequency: 50-60 Hz
Power: 15 VA
Protection: Fuse (internal)
 
Digital Inputs:
Quantity: 3
Type: Static, for dry contact or open collector
Insulation: Optical, 2500 Vrms (UL E67349)
Voltage: 14 VDC internal source
Current: 6 mA
 
Digital Outputs:
Quantity: 4
Type: Relay, Dry contact, N.O.
Insulation: Galvanic,10000 M-ohm
Voltage: max 240 VAC, 48 VDC
Current: max 0.5 A
 
Analog Outputs:
Quantity: 1
Type: Selectable: 0-20 mA, 4-20 mA, 20-0 mA, 20-4 mA
Max Load: 500 ohm
Resolution: 12 bit (4096 divisions)
Linearity: 0.1 %
Insulation: Galvanic, 1500 Vrms
Communication Ports
Quantity: 1
Port #1: RS 232C (for printer use only)
 

.................................................................................................................................
Ramsey
 
Balance LégaleBalance Convoyeur

RAMSEY
Balance de convoyeur 
Modèle : Série-14
-
+/- 0.5% précision

 
Légale pour le Commerce au Canada.

 

.................................................................................................................................
Ramsey

Balance Convoyeur Ramsey

RAMSEY
Modèle : Série-17 
(340k)
Balance de convoyeur haute précision
avec un intégrateur Microtech 2000
-
+/- 0.25% précision (339 k)
 
Part of Micro-Tech 2000 Series
Digital electronics
Auto zero
Auto zero tracking
Auto span
Calibration interval reminder
Linearization
Numerous programmable features
Selectable analog outputs
Selectable analog output delay
Programmable digital inputs
Programmable digital outputs
Independent adjustments of analog output and display damping
Multi-level password protection
CE Approval
UL version of the Micro-Tech 2101 is available as an option
Incline compensation
Moisture compensation
Loadout (Optional)
Retrofittable
Dual speed sensor inputs

.................................................................................................................................
Ramsey
 Balance Convoyeur Microtech
 

RAMSEY
Modèle : MICROTECH 2000 
Intégrateur de balance de convoyeur
+/- 0.25% précision
 

 

.................................................................................................................................
Ramsey

Balance Ramsey Résistante

RAMSEY
Modèle : Série-20 
(132k)
Balance de convoyeur " Très résistant "
+/- 0.5% précision

 
Spécifications techniques
Belt scale combined error   < ±0.5% of nominal load, between 25% and 100% of scale capacity
Load cell combined error   ±0.03% of nominal load
Load cell nominal   50, 100, 250, 500 kg
Load cell maximum load   150 % of nominal load
Load cell breaking load   300 % of nominal load
Nominal temperature range  -10 ÷+40 °C    
Working temperature range  -15 ÷+65 °C
Storage temperature range  -50 ÷+90 °C
Cable lenght  6 m
Nominal output  3.0 mV/V
Nominal output tolerance  ± 0.025 %
Housing protection  IP67
 

 


 

Copyright © 2002-2006 Balances Universelles Balances à Convoyeur